Press the SEL and RST buttons at the same time to get into the menu. You will see "ALErt 1".
Press the SEL button. You will see "ALErt 2".
Press the SEL button. You will see "ALErt 3".
Press the SEL button. You will see "PrESEt".
Press the RST button. You should see "EnAbLE Y." If you see "EnAbLE n", press the SEL button to change this setting.
Press the RST button. You should see "00000000”. Set the value that you want for "ALErt 1". The RST button will move the cursor through the digits one at a time. The SEL button will change the value of the blinking digit. The RST button will move you through the last digit. You should see "Con 1".
Press the SEL button to scroll through the icons. There are eight choices, including no icon (see instruction manual for choices). Once you have selected the icon to use, press the RST button.
You should see "AUto". This is used only in the preset function. When this is set, the count or time will reset when it reaches the preset value. The output will stay on until a front panel or remote reset has occurred.
If you want to use the "AUto" function, press the RST button and you are finished.
If you do not wish to use the "AUto" function, press the SEL button.
You should see "LAtCH". This allows the preset counter to continue counting after it has reached its preset value. Resetting is accomplished with the front panel reset or the remote reset. This will reset the value, output and icon.
If you want to use the "LAtCH" function, press the RST button and you are finished.
If you do not wish to use the "LAtCH" function, press the SEL button.
You should see "rSt UoUt". This allows the user to specify the number of counts after the preset went on that it will go off.
If you want to use the "rSt UoUt" function, press the RST button and you are finished.
Did this answer your question?Thanks for the feedbackThere was a problem submitting your feedback. Please try again later.